Minicom Advanced Systems MINICOM 232 IP Guida Utente

Navigare online o scaricare Guida Utente per Switch di rete Minicom Advanced Systems MINICOM 232 IP. Minicom Advanced Systems MINICOM 232 IP User guide Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 47
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
www.minicom.com
International HQ
Jerusalem, Israel
Tel: + 972 2 535 9666
minicom@minicom.com
North American HQ
Linden, NJ, USA
Tel: + 1 908 486 2100
info.usa@minicom.com
European HQ
Dübendorf, Switzerland
Tel: + 41 44 823 8000
info.europe@minicom.com
Technical support - support@minicom.com
5UM20184 V1 6/08
Smart 216 / 232 IP
User Guide
Vedere la pagina 0
1 2 3 4 5 6 ... 46 47

Sommario

Pagina 1 - User Guide

www.minicom.com International HQ Jerusalem, Israel Tel: + 972 2 535 9666 [email protected] North American HQ Linden, NJ, USA Tel: + 1 908 486 2

Pagina 2 - Table of Contents

SMART 216 / 232 IP 9 9. Connecting the system Figure 5 illustrates the Smart 216 IP system overview. Figure 5 Smart 216 IP system overview 9.1 The

Pagina 3

USER GUIDE 10 To computer’sUSB PortTo computer’sVideo Card Figure 7 ROC USB 9.1.1 Connecting a ROC PS/2 Figure 8 illustrates the ROC PS/2 connectio

Pagina 4 - 1. Welcome

SMART 216 / 232 IP 11 9.1.2 Connecting a ROC USB The ROC USB supports Windows 98 SE and later, MAC, SUN and SGI, and all modern Linux distributions.

Pagina 5 - 3. Key features

USER GUIDE 12 9.5 Connecting the power supply 1. Using the Power cord provided, connect the Smart 216 IP to a socket outlet with grounding connection.

Pagina 6 - 7. The Smart 216 IP unit

SMART 216 / 232 IP 13 In the Settings window navigate downwards using the Tab key. At the bottom of the window, press tab to go to the top of the wind

Pagina 7 - 7.2 Connector table

USER GUIDE 14 11.1 SSL Certificate notes When first connecting, 2 browser security warnings appear. Click Yes to proceed. The first warning disappears

Pagina 8

SMART 216 / 232 IP 15 Figure 14 Targets page By default an Administrator can access all connected Targets, so they all appear on the Targets page. C

Pagina 9 - Figure 4 Bracket connected

USER GUIDE 16 Figure 15 Network >Configuration page 12.1 Network > Configuration Consult your Network Administrator for the network settings.

Pagina 10 - 9. Connecting the system

SMART 216 / 232 IP 17 12.1.2 KVM.net KVM.net is a centralized IP based system for secure control of servers and network devices, power and user admini

Pagina 11 - Figure 7 ROC USB

USER GUIDE 18 Administrator An Administrator has unrestricted access to all windows and settings. An Administrator can change the name and password an

Pagina 12 - Figure 9 ROC USB

SMART 216 / 232 IP 1 Table of Contents 1. Welcome...

Pagina 13 - 10. Setting the IP address

SMART 216 / 232 IP 19 13.3 Blocking a user An alternative to deleting a user is blocking a user. This means that the user’s name and password is store

Pagina 14 - 11 below

USER GUIDE 20 15. Administration > Power Management Where you have a Minicom Serial Remote Power Switch (SRPS), connect it to the Serial 1 port of

Pagina 15 - 11.2 Logging in

SMART 216 / 232 IP 21 16. Administration > Serial Settings Where you have a Serial device connected to the system you must configure the RS232 sett

Pagina 16 - 12. Configuring the system

USER GUIDE 22 Figure 20 User Targets Configuration 2. Select a user from the User drop-down menu. 3. Check the Target servers the user can access (

Pagina 17

SMART 216 / 232 IP 23 Password Policy For local and remote users you have the option of a standard or high security level of password. The table belo

Pagina 18 - Figure 16 User Settings

USER GUIDE 24 20. Maintenance > Switch Upgrade Upgrade the Smart 216 IP firmware to take advantage of new features. Download the firmware from the

Pagina 19 - 13.2 Deleting a user

SMART 216 / 232 IP 25 5. Press , the firmware upgrades. Figure 24 RICCs/RoCs Upgrade 22. Restore Factory Settings You can restore the Smart 216 IP u

Pagina 20 - 13.3 Blocking a user

USER GUIDE 26 23. Set Time & Date The time and date set is used when recording log events (see page 37). To set the time and date: From the menu,

Pagina 21 - Figure 18 Power Management

SMART 216 / 232 IP 27 26. Accessing a Target server Log in to the web interface as explained on page 13. The web interface opens at the Targets page,

Pagina 22 - Figure 19 Serial Settings

USER GUIDE 28 When maximized, the Toolbar can be dragged and dropped to anywhere on the screen, by dragging the icon . When minimized the icon glides

Pagina 23 - 18. Security > Settings

USER GUIDE 2 22. Restore Factory Settings...25 23. Set Time &

Pagina 24

SMART 216 / 232 IP 29 Bandwidth Choose from the following options Adaptive – automatically adapts to the best compression and colors according to the

Pagina 25 - Figure 23 Firmware Upgrade

USER GUIDE 30 Figure 30 Manual Video Adjustments controls Brightness / Contrast - use the scales to adjust the brightness and contrast of the display

Pagina 26 - 22. Restore Factory Settings

SMART 216 / 232 IP 31 26.5 Power cycle Where a Minicom Serial Remote Power Switch is connected to Serial 1 port of the IP Control, you can power manag

Pagina 27 - 24. Backup & Restore

USER GUIDE 32 2. Select the desired sequence and click OK. The sequence appears in the Special Key Manager box. 3. Click OK. The sequence appears in t

Pagina 28

SMART 216 / 232 IP 33 Warning Before synchronizing mouse pointers adjust the video of the Target server, (explained above) otherwise mouse synchroniza

Pagina 29

USER GUIDE 34 Figure 34 Mouse Settings Dialog box 2. Select the Target server’s Operating System and click OK. Instructions and sliders appear. 3. Fo

Pagina 30

SMART 216 / 232 IP 35 26.7.3.2 Advanced – Mouse Emulation Click the Mouse Emulation Dialog box appears, see Figure 35. Do not change these settings

Pagina 31

USER GUIDE 36 Figure 36 Client Configuration Dialog box Pointer type – From the Drop-down menu you can change the Client computer mouse pointer to ap

Pagina 32 - 26.6 Keyboard key sequences

SMART 216 / 232 IP 37 27. The Targets page menu When logging into the system as an Administrator or a User, you reach the Targets page, see Figure 14

Pagina 33

USER GUIDE 38 Navigate through the events pages using the forward or backward arrows, marked as (A) in Figure 38, From the drop down menu, marked as (

Pagina 34

SMART 216 / 232 IP 3 1. Welcome Thank you for buying the Smart 216 / 232 IP system. This system is produced by Minicom Advanced Systems Limited. This

Pagina 35 - 26.7.3.1 USB

SMART 216 / 232 IP 39 Section II Section II explains how to operate the Smart 216 IP system locally via the OSD. 28. The OSD To display the OSD: 1. F

Pagina 36 - 26.8 Adjustments in general

USER GUIDE 40 28.3 Power management hotkey – left Shift, F12 To power manage a server connected to a power management switch: 1. Navigate to the comp

Pagina 37 - 26.10 Full screen mode

SMART 216 / 232 IP 41 28.5 Tuning – F5 You can tune the image of any computer screen from the Main window. To adjust the screen image: 1. Navigate to

Pagina 38 - 27. The Targets page menu

USER GUIDE 42 From In the Settings window you can do the following: KVM.NET MNG – Press the spacebar to toggle between enabling and disabling KVM.net

Pagina 39

SMART 216 / 232 IP 43 28.8 Saving changes to the settings To save changes to the settings and return to the Main window, press Esc. 29. Video resolu

Pagina 40 - 28. The OSD

USER GUIDE 44 30. Technical specifications Operating systems Target server Windows, Novell, Linux, SUN Solaris Client Computer Windows 2000 or higher

Pagina 41 - Figure 41 Power prompt

SMART 216 / 232 IP 45 31. Safety This device contains no serviceable parts. Any servicing of the device must be performed by an authorized Minicom Tec

Pagina 42 - 10 on page 12.]

USER GUIDE 46 Regional Offices Germany Kiel Tel: + 49 431 668 7933 [email protected] France Vincennes Tel: + 33 1 49 57 00 00 info.france@mini

Pagina 43 - 28.7 DDC – F10

USER GUIDE 4 Section I This section explains how to configure and operate the Smart 216 / 232 IP system remotely over IP. Section II on page 39, expla

Pagina 44

SMART 216 / 232 IP 5 Security - Supports the highest security standards for encryption (128 bit SSL and HTTPS) and authentication for remote user and

Pagina 45 - 30. Technical specifications

USER GUIDE 6 7.1 LED and button table LED Function Power Power Indicator Link Unit is connected to the network Remote 1 & 2 Illuminates when

Pagina 46 - 33. WEEE compliance

SMART 216 / 232 IP 7 8. Pre-installation guidelines • Place cables away from fluorescent lights, air conditioners, and machines that are likely to ge

Pagina 47

USER GUIDE 8 8.2 Rack mounting the Smart 216 IP Rack mount the Smart 216 IP using the supplied Rack-mount kit. The brackets can be placed in 2 possibl